Inverter split air/water heat pump for heating, cooling and domestic hot water production
Very high performance even in harsh climates and built-in resistors that can be activated separately from 2KW+2KW (mod.40-50-70) and 2KW+2KW+2KW (mod.90-110) for guaranteed comfort, in any case.
Ariston NET connectivity is included as standard
The Sensys NET system manager and external sensor for thermoregulation are included as standard
180l or 300l boiler with a large coil for the production of domestic hot water
Expansion tank 8l standard
OUTDOOR UNIT
Outdoor unit with silent brushless motor operation for very quiet operation
Twin rotary compressor ensures quiet and efficient operation even at partial loads and harsh climates
Inverter control to adjust the power supplied to that required by the system at all times, minimizing on/off cycles
Optimized product for maximum quietness in any situation
R-410A 3/8" (liquid) and 5/8" (gas) connections
Evaporator with straight fins and Blue Fin treatment for maximum anti-freeze resistance
INDOOR UNIT
Stainless steel gas/water plate heat exchanger
High efficiency continuous configuration circulator
Modular spare electric element (2+2)KW for models 40-50-70 and (2+2+2)KW for models 90-110
Gas and plumbing connections at the bottom
Built-in electronic panel
Expansion tank 8l
Ability to insert hot water kit inside the unit (standard on FLEX packages)
INDOOR UNIT (BOILER)
Steel container with titanium enamel
Active anode (protech) + anti-rust magnesium anode
Inspection flange
Streamer of large dimensions
Standard boiler sensor
Water recirculation (300l model)
specifications
HEAT PUMP PERFORMANCE - HEATING
Thermal power (Min/Nom/Max) (Air temperature -7°C, Water temperature 35/30°C): 2.6/9.1/10.0 kW
COP nominal: 3.4 (for air temperature -7°C, water temperature 35/30°C)
Thermal power (Min/Nom/Max) (Air temperature +7°C, Water temperature 35/30°C): 3.9/8.7/14.0 kW
Nominal COP: 5.3 (for Air Temperature +7°C, Water Temperature 35/30°C)
HEAT PUMP PERFORMANCE - COOLING (for Air Temperature +35°C, Water Temperature 18/23°C)
Thermal power (Min/Nom/Max): 4.6/10.6/13.6 kW
EER nominal: 4.9
HEAT PUMP PERFORMANCE - DOMESTIC HOT WATER (for set temperature +53°C, air temperature +7°C, water temperature 10°C)
COP name: 3.1
Built-in container capacity: 300L
Heating time: 1:52 h:min
Water mixed at 40°C (V40): 434L
Maximum absorbed power single-phase / three-phase (with the built-in resistances of the indoor unit): 11/10.36 kW
ENERGY CLASS
Heating energy class 35°C: A+++
Heating energy class 55°C (Warm climate): A+++
Energy class water for use: A
Intake profile: XXL