ARISTON NIMBUS POCKET 70M NET 11KW...
Air/water monobloc Inverter Heat Pump for heating and cooling, together with Sensys NET System Manager and external sensor for temperature regulation
Reference: 3301184
Air/water monobloc Inverter Heat Pump for heating and cooling, together with Sensys NET System Manager and external sensor for temperature regulation
Send to all Greece
Returns Policy
Use of SSL Encryption
Inverter split air/water heat pump for heating and cooling
Very high performance even in harsh climates.
Ariston NET connectivity is included as standard
The Sensys NET system manager and external sensor for thermoregulation are included as standard
Electric box (light box) for remote access to all connections of the outdoor unit, also placed outdoors.
Plug & Play solution, just add an expansion tank suitable for the installation
Inertia tank and built-in 2kW resistor can be purchased separately, optional (accessory optional)
It can be connected to an external boiler to produce domestic hot water
OUTDOOR UNIT
Outdoor unit with silent brushless motor operation for very quiet operation
Twin rotary compressor ensures quiet and efficient operation even at partial loads and harsh climates
Inverter control to adjust the power supplied to that required by the system at all times, minimizing on/off cycles
Product designed to offer maximum quietness in any condition
Evaporator with straight fins and Blue Fin treatment for maximum frost resistance
Built-in high performance circulator
specifications
HEAT PUMP PERFORMANCE - HEATING
Thermal power (Min/Nom/Max) (Air temperature -7°C, Water temperature 35/30°C): 1/4.1/4.6 kW
COP nominal: 3.3 (for air temperature -7°C, water temperature 35/30°C)
Thermal power (Min/Nom/Max) (Air temperature +7°C, Water temperature 35/30°C): 1.5/3.5/5.7 kW
Nominal COP: 5.1 (for Air Temperature +7°C, Water Temperature 35/30°C)
HEAT PUMP PERFORMANCE - COOLING (for Air Temperature +35°C, Water Temperature 7/12°C)
Thermal power (Min/Nom/Max): 1.1/4.0/4.8 kW
EER name: 3.4
HEAT PUMP PERFORMANCE - COOLING (for Air Temperature +35°C, Water Temperature 18/23°C)
Thermal power (Min/Nom/Max): 1.6/4.8/6.9 kW
EER nominal: 5.4
Maximum absorbed power single-phase / three-phase (with the built-in resistances of the indoor unit): 2.1 kW
ENERGY CLASS
Heating energy class 35°C: A+++
Heating energy class 55°C (Warm climate): A++