LMB G Series - Two-stage: Delivered with gas-train, stabilizer, pneumatic double gas valve and electric servomotor, automatic air adjustment.
LMB G 1300 & LMB G 2000: Valve tightness control system included (VPS 504)
It is necessary to specify the type of fuel, GPL or Natural Gas, as well as the mains pressure
Gas burners 152-979KW
Two-Stage Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Piezostat, Pressure Regulator & Gas Filter, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 60÷205KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 80÷410KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two-Stage Progressive Operation Gas Burner Power 100÷450KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Two Stage Progressive Operation Gas Burner Power 120÷600KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Two Stage Progressive Operation Gas Burner Power 120÷600KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
PELLET Burner Maximum Thermal Power 120KW, with Efficiency Degree 89.22%, Maximum Coverage 2268m3, Maximum PELLET Consumption 26.97kg/h, with 2-Screw Feed System (one inside the Burner and one outside), Double Combustion Flame Head Resistant to High Temperatures, Connection Pipe 90°C, Safety Thermostat to Avoid Backflow, Photocell for Flame Control, Ignition with Electric Resistance
Two Stage Progressive Operation Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Two-Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Single Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
PELLET Burner Maximum Thermal Power 40KW, with Efficiency Degree 86.67%, Maximum Coverage 756m3, Maximum PELLET Consumption 9.3kg/h, with 2-Screw Feeding System (one inside the Burner and one outside), Double Combustion Flame Head Resistant to High Temperatures, Connection Pipe 90°C, Safety Thermostat to Avoid Backflow, Photocell for Flame Control, Ignition with Electric Resistance
Two-Stage Progressive Operation Gas Burner Power 100÷450KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Gas Burners 135 ÷ 1744KW, with aluminum body, high cervical fan, adjustable combustion head for high yields and flame stability, fiber booch, fibro Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Single Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Gas Burners 18÷349KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Gas Burners 18÷349KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40