12KG 4BAR HIGH PRESSURE REGULATOR RED...
12KG 4BAR HIGH PRESSURE REGULATOR RED BUTTERFLY
12KG 4BAR HIGH PRESSURE REGULATOR RED BUTTERFLY
Two-Stage Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Piezostat, Pressure Regulator & Gas Filter, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
400 ÷ 2500KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIABILITY GAS Burner 650 ÷ 3100KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIVENTS Burner 900 ÷ 3600KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
Two Stage Progressive Operation Gas Burner Power 60÷205KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 80÷410KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two-Stage Progressive Operation Gas Burner Power 100÷450KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Two Stage Progressive Operation Gas Burner Power 120÷600KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Industrial Gas Burner Progressive/Proportional Operation Power 400-3600KW
Industrial Gas Burner Progressive/Proportional Power 400-3950KW
Industrial Gas Burner Progressive/Proportional Power 600-5900KW
Industrial Gas Burner Progressive/Proportional Operation Power 1500-10850KW
150KG 2BAR HIGH PRESSURE REGULATOR FOR EXTERNAL ADJUSTMENT
REGULATOR 150KG 2BAR THIL.-THIL.3/4 HIGH PRESSURE EXTERNAL ADJUSTMENT WITH 2 MANOMETERS
REGULATOR 60KG PMAX 8.6BAR 2ND STAGE WITH OPSO & RELIEF
REGULATOR 120KG PMAX 8.6BAR 2ND STAGE INTERNAL ADJUSTMENT WITH OPSO & RELIEF
40KG 45MBAR 1ST & 2ND STAGE INTERNAL REGULATOR WITH OPSO & RELIEF VALVE
100KG HIGH PRESSURE REGULATOR WITH RELIEF VALVE WITHOUT SHUT-OFF
REGULATOR 100KG MEDIUM PRESSURE WITH RELIEF VALVE WITHOUT SHUT-OFF
100KG 110MBAR LOW PRESSURE REGULATOR WITH RELIEF VALVE WITHOUT SHUT-OFF
200 KG 2 BAR HIGH PRESSURE REGULATOR WITH RELIEF VALVE, ALSO COMBINED WITH SHUT-OFF