ARISTON NIMBUS PLUS 50M 2Z NET 7KW...
Air/water monobloc Inverter Heat Pump for heating and cooling, together with Sensys NET System Manager and external sensor for temperature regulation, 8l expansion tank
Reference: 3300921
Air/water Inverter Split Heat Pump for heating, cooling and Domestic Hot Water production, together with Sensys NET System Manager and external sensor for temperature regulation, with 180l or 300l Boiler and 8l expansion tank, Three-phase
Send to all Greece
Returns Policy
Use of SSL Encryption
Inverter split air/water heat pump for heating, cooling and domestic hot water production
Very high performance even in harsh climates and built-in resistors that can be activated separately from 2KW+2KW (mod.40-50-70) and 2KW+2KW+2KW (mod.90-110) for guaranteed comfort, in any case.
Ariston NET connectivity is included as standard
The Sensys NET system manager and external sensor for thermoregulation are included as standard
180l or 300l boiler with a large coil for the production of domestic hot water
Expansion tank 8l standard
OUTDOOR UNIT
Outdoor unit with silent brushless motor operation for very quiet operation
Twin rotary compressor ensures quiet and efficient operation even at partial loads and harsh climates
Inverter control to adjust the power supplied to that required by the system at all times, minimizing on/off cycles
Optimized product for maximum quietness in any situation
R-410A 3/8" (liquid) and 5/8" (gas) connections
Evaporator with straight fins and Blue Fin treatment for maximum anti-freeze resistance
INDOOR UNIT
Stainless steel gas/water plate heat exchanger
High efficiency continuous configuration circulator
Modular spare electric element (2+2)KW for models 40-50-70 and (2+2+2)KW for models 90-110
Gas and plumbing connections at the bottom
Built-in electronic panel
Expansion tank 8l
Ability to insert hot water kit inside the unit (standard on FLEX packages)
INDOOR UNIT (BOILER)
Steel container with titanium enamel
Active anode (protech) + anti-rust magnesium anode
Inspection flange
Streamer of large dimensions
Standard boiler sensor
Water recirculation (300l model)
specifications
HEAT PUMP PERFORMANCE - HEATING
Thermal power (Min/Nom/Max) (Air temperature -7°C, Water temperature 35/30°C): 1.7/7.0/8.0 kW
COP nom: 3.2 (for Air Temperature -7°C, Water Temperature 35/30°C)
Thermal power (Min/Nom/Max) (Air temperature +7°C, Water temperature 35/30°C): 2.6/6.4/11.0 kW
COP nom: 5 (for Air Temperature +7°C, Water Temperature 35/30°C)
HEAT PUMP PERFORMANCE - COOLING (for Air Temperature +35°C, Water Temperature 18/23°C)
Thermal power (Min/Nom/Max): 3.1/7.5/12.0 kW
EER name: 5
HEAT PUMP PERFORMANCE - DOMESTIC HOT WATER (for set temperature +53°C, air temperature +7°C, water temperature 10°C)
COP nominal: 2.6
Built-in container capacity: 180L
Heating time: 1:30 h:min
Water mixed at 40°C (V40): 247L
Maximum absorbed power single-phase / three-phase (with the built-in resistances of the indoor unit): 7.22/7.7 kW
ENERGY CLASS
Heating energy class 35°C: A+++
Heating energy class 55°C (Warm climate): A+++
Energy class water for use: A
Intake profile: XL