ARISTON NIMBUS PLUS 40S NET 6KW SINGLE-PHASE SPLIT TYPE HEAT PUMP

Reference: 3300930

€3,840.00
VAT included Immediate Delivery

Air/water Split Inverter Heat Pump for heating and cooling, together with Sensys NET System Manager and external sensor for temperature regulation, 8l expansion tank

Quantity
Immediately available

 

Send to all Greece

 

Returns Policy

 

Use of SSL Encryption

Inverter split air/water heat pump for heating and cooling

Very high performance even in harsh climates and built-in resistors that can be activated separately from 2KW+2KW (mod.40-50-70) and 2KW+2KW+2KW (mod.90-110) for guaranteed comfort, in any case.

Ariston NET connectivity is included as standard

The Sensys NET system manager and external sensor for thermoregulation are included as standard

Expansion tank 8l standard

OUTDOOR UNIT

Outdoor unit with silent brushless motor operation for very quiet operation

Twin rotary compressor ensures quiet and efficient operation even at partial loads and harsh climates

Inverter control to adjust the power supplied to that required by the system at all times, minimizing on/off cycles

Optimized product for maximum quietness in any situation

R-410A 3/8" (liquid) and 5/8" (gas) connections

Evaporator with straight fins and Blue Fin treatment for maximum anti-freeze resistance

INDOOR UNIT

Stainless steel gas/water plate heat exchanger

High efficiency continuous configuration circulator

Modular spare electric element (2+2)KW for models 40-50-70 and (2+2+2)KW for models 90-110

Gas and plumbing connections at the bottom

Built-in electronic panel

Expansion tank 8l

Ability to insert hot water kit inside the unit (standard on FLEX packages)

specifications

HEAT PUMP PERFORMANCE - HEATING

Thermal power (Min/Nom/Max) (Air temperature -7°C, Water temperature 35/30°C): 1/4.1/4.5 kW

COP nominal: 3.3 (for air temperature -7°C, water temperature 35/30°C)

Thermal power (Min/Nom/Max) (Air temperature +7°C, Water temperature 35/30°C): 1.5/3.5/5.7 kW

Nominal COP: 5.1 (for Air Temperature +7°C, Water Temperature 35/30°C)

HEAT PUMP PERFORMANCE - COOLING (for Air Temperature +35°C, Water Temperature 7/12°C)

Thermal power (Min/Nom/Max): 1.1/4.0/4.8 kW

EER name: 3.4

HEAT PUMP PERFORMANCE - COOLING (for Air Temperature +35°C, Water Temperature 18/23°C)

Thermal power (Min/Nom/Max): 1.6/4.8/6.9 kW

EER nominal: 5.4

Maximum absorbed power single-phase/three-phase (with the built-in resistances of the indoor unit): 6.03KW

ENERGY CLASS

Heating energy class 35°C: A+++

Heating energy class 55°C (Warm climate): A++

3300930
20 Items

Data sheet

POWER
6 KW
POWER SUPPLY
Single phase
SYSTEM
Split
DOMESTIC HOT WATER
Not available
ZONES
1

Specific References

20 other products in the same category: