Reference: 04150
Single Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Send to all Greece
Returns Policy
Use of SSL Encryption
Specifications
Single stage operation.
Ability to achieve optimal combustion values by adjusting air and head position.
Easy maintenance due to the fact that the dispersion unit is accessible without the need to remove the burner from the boiler.
Long pipe with rolling flange to adapt the burner to any type of boiler.
Mechanical air intake adjustment damper.
Damper with total block at the burner pauses to reduce thermal losses.
CE gas line equipped with: Operating and safety solenoid valve, minimum gas pressure switch, pressure regulator and gas filter.
Mistake-proof quick connectors for burner and gas line connection.
Gas line connection from above.
Ionization electrode for flame detection and provision for micro-ammeter connection (mA)
Seven-pole quick connector for electrical and thermostatic connection.
Degree of electrical protection IP40
Combinations
16.6-42.7 KW/ MBC65/01 BTG 3
Multiblock Cross Section: 1/2"
Gas Type: GPL/LPG
30.6-56.3 KW/ MBC65/01 BTG 6
Multiblock Cross Section: 1/2"
Gas Type: GPL/LPG
48.8-75 KW/ MBC65/01 BTG 11
Multiblock Cross Section: 1/2"
Gas Type: GPL/LPG
48.8-99 KW/ MB405 BTG 11
Multiblock Cross Section: 3/4"
Gas Type: GPL/LPG
35-75 KW/ MBC65/01 BTG 12
Multiblock Cross Section: 1/2"
Gas Type: GPL/LPG
35-115 KW/ MB405 BTG 12
Multiblock Cross Section: 3/4"
Gas Type: GPL/LPG
50-160 KW/ MB405 BTG 15
Multiblock Cross Section: 3/4"
Gas Type: GPL/LPG
60-165 KW/ MB405 BTG 20
Multiblock Cross Section: 3/4"
Gas Type: GPL/LPG
60-205 KW/ MB407 BTG 20
Multiblock Cross Section: 3/4"
Gas Type: Gas
100-280 KW/ MB405 BTG 28
Multiblock Cross Section: 3/4"
Gas Type: GPL
100-225 KW/ MB407 BTG 28
Multiblock Cross Section: 3/4"
Gas Type: Gas
100-280 KW/ MB410/31 BTG 28
Multiblock Cross Section: 1 1/4"
Gas Type: Gas
Single Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Two-Stage Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Piezostat, Pressure Regulator & Gas Filter, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
400 ÷ 2500KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIABILITY GAS Burner 650 ÷ 3100KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIVENTS Burner 900 ÷ 3600KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
Two Stage Progressive Operation Gas Burner Power 60÷205KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 80÷410KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two-Stage Progressive Operation Gas Burner Power 100÷450KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Two Stage Progressive Operation Gas Burner Power 120÷600KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Industrial Gas Burner Progressive/Proportional Operation Power 400-3600KW
Industrial Gas Burner Progressive/Proportional Power 400-3950KW
Industrial Gas Burner Progressive/Proportional Power 600-5900KW
Industrial Gas Burner Progressive/Proportional Operation Power 1500-10850KW
Gas Burners 135 ÷ 1744KW, with aluminum body, high cervical fan, adjustable combustion head for high yields and flame stability, fiber booch, fibro Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Two-Stage Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Piezostat, Pressure Regulator & Gas Filter, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
45-550KW Power Two-Stage Progressive Burner with High Quality Materials Guarantees Safe Operation, with a Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
Gas Burners 18÷349KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
45-550KW Power Two-Stage Progressive Burner with High Quality Materials Guarantees Safe Operation, with a Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
Single Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Analog Operation Burner Power 76-2400KW with High Level Materials Quality Guarantees Safe Operation, with Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
Two-Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Two Stage Progressive Operation Gas Burner Power 120÷600KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
Analog Operation Burner Power 76-2400KW with High Level Materials Quality Guarantees Safe Operation, with Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust