Reference: 04199
Gas burners 11.9÷320KW
Send to all Greece
Returns Policy
Use of SSL Encryption
The burners are delivered with a mutliblock containing: gas operating valve, gas safety valve, air pressure switch, gas and stabilizer with filter
The two-stage burners have an electric servomotor, with automatic air regulation
VPS 504 valve tightness test kit from EM 3-E to EM 50/2-E
It is necessary to specify the type of fuel, GPL or Natural Gas, as well as the mains pressure
Gas burners 11.9÷320KW
Two-Stage Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Piezostat, Pressure Regulator & Gas Filter, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
400 ÷ 2500KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIABILITY GAS Burner 650 ÷ 3100KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
DIVENTS Burner 900 ÷ 3600KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
Two Stage Progressive Operation Gas Burner Power 60÷205KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 80÷410KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Air Filter i , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two-Stage Progressive Operation Gas Burner Power 100÷450KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Two Stage Progressive Operation Gas Burner Power 120÷600KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP40
Two Stage Progressive Operation Gas Burner Power 170÷850KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Electric Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter A element , Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABLE Burner Burner 240 ÷ 1200KW, with the ability to adjust air and head position, easy maintenance due to the position of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
400 ÷ 2100KW Gas Burner, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP44
Industrial Gas Burner Progressive/Proportional Operation Power 400-3600KW
Industrial Gas Burner Progressive/Proportional Power 400-3950KW
Industrial Gas Burner Progressive/Proportional Power 600-5900KW
Industrial Gas Burner Progressive/Proportional Operation Power 1500-10850KW
290-2290KW Power Two-Stage Progressive Burner with High Quality Materials Guarantees Safe Operation, with a Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
DIABILITY GAS Burner 300 ÷ 1500KW, with the ability to adjust air and head position, easy maintenance due to the location of the scattering unit, rolling flange, electric air damp, gas line with electromagnetic safety valve, ministers of gas Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, Four Pole Coupler for 2nd Stage, IP54
45-550KW Power Two-Stage Progressive Burner with High Quality Materials Guarantees Safe Operation, with a Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
Industrial Gas Burner Progressive/Proportional Operation Power 400-3600KW
Gas Burner Two-Stage Progressive or Analog Operation, Power 49÷250 KW, with Safety Control Panel with Microprocessor that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
290-2290KW Power Two-Stage Progressive Burner with High Quality Materials Guarantees Safe Operation, with a Microprocessor Control Panel that indicates the operation and Diagnoses the Causes of Errors, with Reduced Noise, Easy to Install and Adjust
Single Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40
Gas Burners 18÷349KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Gas Burners 116÷630KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Gas Burners 18÷349KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Gas Burners 18÷349KW, with Aluminum Body, High Manometric Fan, Adjustable Combustion Head for High Efficiency and Flame Stability, INOX Flap, INOX Steel Flame Spreader, Air Circuit Safety Pressure Switch that blocks the Burner in the event of Fan Damage or Malfunction, Complete Gas Ramp with Safety Valve and Regulating Valve, Ionization Sensor for Flame Control, Servo Motor, Movable Tamper for Total Blocking in Standby State to Minimize Energy Losses, IP40
Two-Stage Gas Burner Power 16.6÷280KW, with Air and Head Position Adjustment, Easy Maintenance due to Dispersion Unit Position, Rolling Flange, Mechanical Air Damper, Gas Line with Safety Solenoid Valve, Minimum Gas Pressure Regulator, Pressure Regulator & Filter Gas, Ionization Electrode for Flame Detection, Seven Pole Quick Coupler, IP40