RADIANT R1K 50 POWERTECH 50KW WALL-MOUNTED CONDENSING GAS BOILER

Reference: 03490

€3,170.00
VAT included Immediate Delivery

Wall-Mounted Condensing Gas Boiler for Heating and Hot Water Production (with the appropriate accessory), with an Efficiency Rate of up to 108%, Compact Dimensions, with INOX heat exchanger, Brass Fittings, Silent Operation, with DIGITECH LCD Screen with large letters and icons, Ability to Adjust Temperature per Degree with High Accuracy, Self-diagnosis Function

Quantity
Immediately available

 

Send to all Greece

 

Returns Policy

 

Use of SSL Encryption

The use of the INOX heat exchanger, the copper pipes, the brass fittings for mechanical tightening as well as the individual high-quality components give a homogeneous whole that contributes to the smooth operation of the boiler and its durability over time.

Its compact dimensions allow installation in places with limited available space. Its simple yet modern design helps it to integrate perfectly into any space.

The combination of the front and perimeter thermal insulation, the sound-absorbing funnel and the newly designed air/gas mixer ensure the boiler extremely low noise levels (<52dB at 100% of its operation) both during ignition and during of its operation.

The DIGITECH® SYSTEM displays the temperatures and boiler functions in the most easy-to-use and easy-to-read way, with large letters and icons. Ability to set the desired temperature per degree with great precision for economy. It has the ability to control: external sensors, solar panels, sensors for external boiler, autonomy valves and many additional components.

The DIGITECH® electronic board has an easy-to-read display. All information is given in large letters and icons so that the information is given quickly and easily. The design of the buttons combined with the color choice of the cover give a perfect final aesthetic result and make handling it an easy task.

DIGITECH® offers continuous control of operating parameters and quick identification of potential malfunctions through special fault indication codes. With the built-in memory function, you inform the technician about the latest malfunctions of the boiler, so everyone always has a picture of its operation.

The DIGITECH® electronic board allows us to connect the boiler with a multitude of digital accessories in order to adjust its operation, based on the needs of the installation. Accessories include temperature sensors, wireless or wired room thermostats, with OT+, with Wi-Fi, etc.

The components of the wall-mounted boiler are arranged in such a way that they are all easily accessible, for checking them and for any repairs that may arise, e.g.

-the closed expansion tank is on the side with the valve in front, for easy maintenance.

-the hydraulic connection of the closed expansion tank is at the top so that it can be easily replaced.

-the transformer is not part of the management board, as a result of which its replacement is done easily, quickly and at a very low cost in contrast to the replacement of the board that has the transformer built in, which is a time-consuming and costly process.

- all parts are connected with brass fittings, resulting in easy repair.

- the special sound-absorbing funnel helps reduce noise.

-all components are made of branded high-quality materials, eg Callefi.

specifications

Exhaust type: B23P, B33, C13, C33, C43, C53, C63, C83, C93

Energy efficiency 92/42/CEE: ****

Energy efficiency EN13203-1: ***

Maximum nominal heating power: 50 kW

Minimum nominal heating power: 5 kW

Delivered thermal power - 60/80°C: 49.19kW

Efficiency at 100% rated power 60/80°C: 98.37%

Efficiency at 100% rated power 30/50°C: 106.8%

Efficiency at 30% rated power - return 47°C: 102.8%

Efficiency at 30% rated power - return 30°C: 108.83%

COMBUSTION ELEMENTS

Combustion efficiency (100% rated power): 97.9%

Combustion efficiency (100% Minimum rated power): 98%

Chimney losses with burner in operation (100% rated power): 2.1%

Chimney losses with burner in operation (Minimum rated power): 2%

Chimney losses with burner off: 0.02%

Cover losses (100% rated power): 0.1%

Cover losses (100% minimum rated power): 1.49%

Cover losses with burner on: 0.03%

Flue gas temperature at rated thermal output: 66°C

Flue gas temperature at minimum rated thermal power: 55°C

Exhaust gas mass at rated thermal power: 22.19 g/s

Exhaust gas mass at minimum rated thermal output: 2.28 g/s

CO2 at rated thermal output - G20: 9.31%

CO2 at minimum heat output - G20: 9.07%

CO2 at rated heat output - G30: 11.3%

CO2 at minimum heat output - G30: 10.7%

CO2 at rated thermal output - G31: 10.46%

CO2 at minimum heat output - G31: 9.7%

CO at rated heat output: 69ppm

CO at minimum rated heat output: 2ppm

CO at rated thermal power (0% O2) - Weighted : 9ppm

NOx class: 5

NOx: 35ppm

NOx: 63mg/kWh

HEATING CIRCUIT

Adjustable heating temperature: 30-80/25-45°C

Maximum heating operating temperature: 95°C

Maximum heating operating pressure: 5bar

Minimum heating operating pressure: 0.3bar

Expansion tank

: 4.6l

Dimensions W/W/H: 410/485/640mm

Weight: 56kg

HYDRAULIC CONNECTIONS

Departure 1"1/4

Return 1" 1/4

Gas 3/4"

Safety valve outlet 3/4"

Condensate discharge Φ25

EXHAUST GAS DISTRIBUTION CONNECTIONS

Maximum available fan pressure 100Pa

Minimum available fan pressure 30 Pa

Maximum lead length Φ80- Horizontal duct 25m

Maximum lead length Φ80- Vertical duct 25m

Maximum lead length Φ80/125- Horizontal Homoax. 10m

Maximum lead length Φ80/125- Vertical. Coaxial. 10m

ELECTRICAL CHARACTERISTICS

Voltage/frequency 230/50 V/Hz

Maximum absorbed power 108W

Absorbed pump electric power 55W

Absorbed electrical power with boiler active 4W

Degree of electrical protection IPX4D

GAS SUPPLY

Nominal supply pressure G20 : 20mbar

Maximum supply pressure G20 : 23mbar

Minimum supply pressure G20 : 15mbar

Fuel consumption G20: 5.29m3/h

Nominal supply pressure G30 : 30mbar

Maximum supply pressure G30 : 35mbar

Minimum supply pressure G30 : 25mbar

Fuel consumption G30: 3.94kg/h

Nominal supply pressure G31 : 37mbar

Maximum supply pressure G31: 45mbar

Minimum supply pressure G31 : 25mbar

Fuel consumption G31: 3.88kg/h

03490
20 Items

Data sheet

POWER
36-65 kW
50 KW
INSTALLATION
Wall mounted
POWER SUPPLY
LPG
Natural gas
OPERATION MODES
Heating + Domestic Hot Water

Specific References

related products

20 other products in the same category: