COMFORT OF HOT WATER USE
• Possibility of connection to an external indirect cylinder, with solar integration, for single installation with special diverter valve kit and installation in array.
• Comfort setting of domestic hot water directly from the boiler (single installation)
HEATING COMFORT
• Performance up to 108% and energy saving up to 35%.
• **** stars for combustion performance according to EN 92/42.
• Full premix analog burner with stainless exchanger
• Reduced pollutant emissions, class NOx5 (NO<30 mg/kWh) which corresponds to a reduction of 40% for CO2 and 75% for NOx compared to old generation boilers.
• S.R.A. proportional climate control of temperature in two heating zones, activated directly from the control panel, capable of optimizing performance levels according to ambient and room temperatures (single installation).
• Possibility to connect to a heating system thanks to EBUS2 (hydraulic devices, temperature control accessories).
• Operation and programming control via LCD screen, with text menu to scroll through: operating temperatures, self-diagnosis, daily and weekly programming, setup information and log of most recent errors (single installation).
• Electronic control unit for installation in an array, which allows: climate configuration and room temperature regulation, temperature and power control, ignition priority control to ensure balance of use of the generators, control of the hot water production circuit with an external cylinder, etc.
EASE OF USE AND INSTALLATION
• Extremely small dimensions and weight for a generator that offers so much power: only 44 cm wide.
• Self-adjusting two-speed proportional circulation pump.
• Easier Start: Automatic ventilation function and combustion analysis with direct access.
• Simplified maintenance: front access to all components.
• Full range of installation, plumbing, control and exhaust accessories available. They are all already dimensioned and easy to apply.
• Integration with Expert Control: new and intuitive climate control to manage 3 circuits based on space and/or outside temperature for greater comfort and energy savings.
• Designed for wired analog thermostats - bus interface board included.
•Butane conversion kit included
ENERGY SAVING AND RESPECT FOR THE ENVIRONMENT
• Up to 23% energy savings with Expert Control and SRA mode
• Up to 35% energy savings with analog regulation, external sensor and underfloor heating (array installation)
• Reduced emissions
specifications
Max/Min rated heating power: 41/12.3kW
Max/Min thermal power (80-60°C): 39.8/11.8kW
Max/Min thermal power (50-30°C): 43.6/13.2kW
Max/Min thermal power (40-30°C): 43.7/13.2kW
Combustion efficiency (in exhaust gases): 97.5%
Performance at max/min nominal load (60/80°C): 97/96.2%
Efficiency at max/min nominal load (50/30°C): 106.4/107.5%
Performance at max/min nominal load (40/30°C): 106.5/107.4%
Efficiency at 30% of nominal charge with 30°C DHW return: 107.4%
Efficiency at 30% of nominal charge with 47°C DHW return: 104.8%
Combustion efficiency stars (Directive 92/42/EEC):****
Max. heat loss through casing (ΔT=70°C): 0.24%
Heat loss through chimney with active boiler: 2.5%
Heat loss through the chimney with the boiler off: <0.1%
shows
Maximum exhaust gas flow rate (G20): 74.3kg/h
Net discharge pressure: 130Pa
Exhaust temperature (G20): 68°C
CO2 content (G20): 9%
CO content (0% 02):88ppm
O2 content (G20): 4.8%
NOx class: 5
Excess air (80-60°C):27.2%
HEATING CIRCUIT
Maximum pressure for minimum heating level: 1 bar
Maximum pressure for maximum heating level: 4 bar
Water content: 3.9l
Max/Min heating temperature (high temp.): 85/35°C
Max/Min heating temperature (low temp.): 45/20°C
ENERGY CLASS A
CONDENSATION
Maximum condensate production: 5l/h
Concentrates pH: 3.2
ELECTRICAL COMPONENTS
Power supply voltage/frequency: 230/50 V/Hz
Total power consumption: 148W
Degree of protection of electrical circuit: IPX4D
Dimensions H/W/D: 745/440/511mm
Weight: 45kg